Gamma4-carousel-desktop
Gamma4-carousel-mobile

Gamma4â„¢Ìý
Hip Fracture Nailing System

Available in three sizes, short, intermediate and long

Ìý

Cephalomedullary nailing system for the treatment of intertrochanteric fractures as well as a wide range of proximal femur fractures and associated femoral shaft fractures.

When it really matters,
Every advantage counts

Just like all other top-class professionals, you face critical decisions every day, striving to help rebuild lives as effectively and efficiently as possible, always relying upon next level tools and information. At Stryker, we make continuous, often small enhancements to our processes and products which, when added together, can make all the difference to our customers' performance and their patients' lives.

  

Trochanteric Nail
surgical animation

The Gamma4 Trochanteric Nail is a hip fracture solution for treatment of fractures in the intracapsular, trochanteric, subtrochanteric and shaft regions of the femur (including osteoporotic and osteopenic bone).

  

  

redefined-nail-design

Redefined
nail design

  • Pre-inserted and cannulated set screw
  • SOMA designed1
  • Length dependent Radius of curvature (RoC) Long Nails .75-1.351
  • Chamfered distal tip
  • Shorted proximal body by 5mm
  • Wide distal diameter range: 9, 10, 11, 12, 13 & 15mm

  

  

Streamlined
workflow

  • Precision Pinâ„¢ 3.9mm, has a drill top with 5mm threads
  • Measure to the tip of Precision Pinâ„¢
  • The Precision Pinâ„¢ with its larger diameter reduces the likelihood of deflection/skiving by 66% compared to a standard k-wire1
  • The reduced pin deflection facilitates lag screw placement centrally through the nail according to the pre-planned trajectory, decreasing the risk of implant notching due to a deflected pin2
streamlined-workflow

  

  

integrated-instrument-platform

Integrated
instrument platform

  • We have a streamlined portfolio where we utilize the existing IMN Basic set
  • All nails have a dedicated distal targeting device
  • Reduced inventory
  • Lag Screw measurement off Precision Sleeveâ„¢
  • Single Lag Screw Driver

  

RC Lag Screw

  • When rotational stability and fixation performance is desired, the RC Lag Screw may be used4
  • Consists of three parts: RC Lag Screw, U-blade and U-blade end cap
  • When assembled, the width of the tip increases to 12.5mm instead of 10mm due to the spread of the U-blade
RC-lag-screw

  

integrated-instrument-platform

Anti-rotation system

  • Designed to provide stability in rotationally unstable femoral neck fragments
  • Provides temporary fixation of the femoral head during reaming and Lag Screw insertion

  

Gamma4 OpTech mock up-gold
Discover Gamma4

Stay in touch

Be the first one to hear about Gamma4 updates in ¾ÅÉ«ÊÓÆµ
Thank you!